PHOTO COLLECTION
Drying Unit:
Silica gel, layer of 1 m height and 2.5 m diameter; 70 kW heating system for regeneration
(end temp. 150°C)
Test Section:
1800mm×350mm×100mm
Vacuum Tanks:
120 m³
Pump Unit:
2300 m³/h (80% vacuum) + 700 m³/h
(95% vacuum)
Evacuation time:
~ 25, 10 and 5 minutes depending on used pomp
Blow down time at 100mm¤100mm sonic throat:
~ 22 sec.
Measurement Equipment:
Pressure:
- digital barometer DRUCK;
- pressure transducers (KULITE, DRUCK)
  with KULITE signal conditioners;
- intelligent pressure scanners PSI System 9010,
  4×16 channels;
- computer controlled pneumatic probe
  transportation system for boundary layer
  measurements.
Optics:
- Schlieren system;
- Mach-Zehnder interferometer;
- CCD technology for picture acquisition
  and analysis;
- PIV system of DANTEC.
Main      Staff      Transonic Wind Tunnel      Numerical Tools      Thematic Interests      Cooperation
Last update: 13.10.2003    Copyright © 2003 IMP PAN. All rights reserved.